33 V-12 water pump shaft nut packing
#1
Not too shy to talk
Not too shy to talk

68amxgopac
See User information
Hello again -
Had some leakage around the packing nut on the 33 V-12 .
Looked like it had been gooped up with plumbers putty or something , and tightened in all the way by someone , nut flange was tight right up against the pump housing. I looked at the 37 and can see that shouldn't be the case as it shows several threads proud 0f the housing.
I got a rebuild kit from MM , and was going to pull the whole thing , BUT after reading the links to that work here , I opted for just redoing the packing , ask me why ? lol
Anyway , has anyone just replaced the packing alone ? should it be cut to fit in the recess in the back side of the nut or cut to fit inside the hole in the housing ? Just curious and looking for tips before I make the cut and fit .
I did some measurements and it looks like there is only a 1/16" clearance between the end of the shaft and the radiator if I was to pull the whole thing out as a unit. Beyond that I could shave a 1/16" off the 2 bottom longer studs that protrude out of the nut when tight also to gain more , but I am sure the whole thing may be solved by just the packing issue. - fingers crossed !

Thanks

Posted on: 10/16 13:39
 Top  Print   
 


Re: 33 V-12 water pump shaft nut packing
#2
Home away from home
Home away from home

TxGoat
See User information
If the bearings are reasonably tight and the shaft is not scored or corroded, repacking will usually fix the problem. The Literature archive on this website has a lot of service information that will be helpful.

Posted on: 10/16 16:44
 Top  Print   
 


Re: 33 V-12 water pump shaft nut packing
#3
Not too shy to talk
Not too shy to talk

68amxgopac
See User information
Thanks
I had good luck with just doing the packing so far.
Took my time cleaned up everything that I could.
First time I cut the packing a little long and then tried shoving it in , it's got to be cut just right or the ends overlap even the tiniest bit causes trouble it seems.
Holding well , tiny single drip off the shaft setting overnight , better than a puddle in the drip pan.

I opted not to try pulling the pump , if this holds I will be happy.

Posted on: 10/18 21:49
 Top  Print   
 


Re: 33 V-12 water pump shaft nut packing
#4
Home away from home
Home away from home

todd landis
See User information
Cut the ends of the rope at a bit of an angle so they butt up against each other on a bit of an angle. Make sure you use some sort of pick to get all of the old rope out. The modern packing as I remember will not work. There are some sellers that sell the correct packard packing.

Posted on: 10/18 22:09
 Top  Print   
 









- The following Google Ad-Sense Advert helps fund the cost of providing this free resource -
- Logged in users will not see these. Please Join and Donate to help support the website -
Search
Recent Photos
Photo of the Day
Recent Registry
Upcoming Events
32nd Annual Florida Packard Club Meet
01/26/2025
46th Annual Texas Packard Meet
04/03/2025 - 04/06/2025
Packard Salon - Calling All Twelves
05/27/2025 - 05/29/2025
58th Annual National Meet
05/31/2025 - 06/06/2025
AACA Fall Meet (Hershey)
10/06/2025 - 10/10/2025
Website Comments or Questions?? Click Here Copyright 2006-2024, PackardInfo.com All Rights Reserved