Re: Flapper Valve Adjustment for Ventilation System
|
||||
---|---|---|---|---|
Forum Ambassador
|
You should be able to move the entire cable at one end or the other--depending on which side has the most room.
Move the lever to the heat or off position and then loosen the screw holding the cable clamp at the flapper end. Slide the entire cable in the clamp until the flapper is totally in position and retighten. It might take a try or two to check and move the lever again if it didn't go to stop the first time. If there is not enough room to move cable without running the housing out of the clamp, loosen the other end and slide the housing slightly on the wire to provide a bit more area. If doing that, be careful not to restrict the approx 1 1/2 inch of total travel. If that adjustment looks OK, also look at the flapper rubber. Sometimes old rubber cracks & breaks off or takes a set & warps so air passes. The rubber piece can be replaced either with newly made ones from Steele or just plain sheet rubber cut to pattern. EDIT: I don't remember if your model Clipper has the two 51-3 dual function levers or the four 54-6 separate function levers----While there is a difference in lever mechanisms, a procedure is given for adjusting the 51 dual function lever setup. The basics & explanation for some low heat problems are applicable to later ones as well.packardinfo.com/xoops/html/downloads/SC/SC-VOL25NO2.pdf
Posted on: 2011/10/14 8:55
|
|||
Howard
|
||||
|
Re: Flapper Valve Adjustment for Ventilation System
|
||||
---|---|---|---|---|
Webmaster
|
I found the flapper rubber on my '54 was petrified and pieces of it had broken off. One of the PI Chapters sells the replacement flapper rubber as well. I think I have pictures on my blog of me replacing the rubber in mine. It makes a world of difference when they seal correctly.
Just a note this will take a couple of hours to replace as you have to remove the sections of ducting where the flappers are located, and then remove the flappers themselves, and then remove all the staples that hold the two halves of each flapper together. I was able to careful pry up the legs of all the staples so I could pull them out and reuse them. I always have this vision of some guy at the factory with a huge comical oversized Swingline stapler assembling these back in the day.
Posted on: 2011/10/14 10:10
|
|||
-BigKev
1954 Packard Clipper Deluxe Touring Sedan -> Registry | Project Blog 1937 Packard 115-C Convertible Coupe -> Registry | Project Blog |
||||
|
Re: Flapper Valve Adjustment for Ventilation System
|
||||
---|---|---|---|---|
Forum Ambassador
|
Quote:
I always have this vision of some guy at the factory with a huge comical oversized Swingline stapler assembling these back in the day. Actually, you're probably not that far off with such a vision. Electric-powered staplers have long been available and still used for many purposes: binding books and catalogs, securing cardstock headers to poly-bagged items for retail display, etc. Basically, the work is supported by a "anvil", and the stapler head is activated by either the work as it contacts a pressure switch or the operator by a foot pedal switch. The simpler units are loaded with staples just like a desktop stpale, but with heavy-duty staples. More complicated, automated systems feed straight wire off a spool to create a staple on the fly.
Posted on: 2011/10/14 12:12
|
|||
|