Re: 1941 One-Sixty Not Charging
|
||||
---|---|---|---|---|
Forum Ambassador
|
With the motor running at a reasonably fast idle, use a short jumper wire and quickly jump the Field terminal on the regulator to ground. If the ammeter shows full charge, the generator is OK and the regulator is at fault. If it shows nothing, the generator is at fault. Do not relace a positive ground regulator with a negative ground regulator.
Or if you wish, Ross has described several times recently his quick method of testing a generator by seeing if it will "motor". A quick search should find those posts.
Posted on: 2012/5/2 13:23
|
|||
|
Re: 1941 One-Sixty Not Charging
|
||||
---|---|---|---|---|
Forum Ambassador
|
G'day sbarnes,
to PackardInfo and for including your '41 One-Sixty Super Eight 5 Passenger 4 Door Touring Sedan in the Packard Owner's Registry.
Posted on: 2012/5/2 16:18
|
|||
Mal
/o[]o\ ==== Bowral, Southern Highlands of NSW, Australia "Out of chaos comes order" - Nietzsche. 1938 Eight Touring Sedan - SOLD 1941 One-Twenty Club Coupe - SOLD 1948 Super Eight Limo, chassis RHD - SOLD 1950 Eight Touring Sedan - SOLD What's this? Put your Packard in the Packard Vehicle Registry! Here's how! Any questions - PM or email me at ozstatman@gmail.com |
||||
|
Re: 1941 One-Sixty Not Charging
|
||||
---|---|---|---|---|
Home away from home
|
Yes, both tests are needed to absolutely isolate the culprit component(s). They are easy to do.
(o[]o)
Posted on: 2012/5/2 16:34
|
|||
We move toward